2AD-FTV COOLING > SERVICE DATA



Thermostat:

Condition
Specified Condition
Standard value opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)

Cooling Fan Motor:

Item
Condition
Specified Condition
No. 1 cooling fan motor
20°C (68°F)
10.6 to 16.6 A
No. 2 cooling fan motor
20°C (68°F)
7.8 to 11.8 A

Cooling Fan Relay:

Item
Tester Connection
Specified Condition
No. 1 fan relay
3 - 5
Standard resistance: 10 kΩ or higher
3 - 5
Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
No. 2 fan relay
3 - 4
Standard resistance: Below 1 Ω
3 - 5
Standard resistance: 10 kΩ or higher
3 - 4
Standard resistance: 10 kΩ or higher (When battery voltage is applied to terminals 1 and 2)
3 - 5
Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
No. 3 fan relay
3 - 5
Standard resistance: 10 kΩ or higher
3 - 5
Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)

Radiator Cap:

Item
Condition
Specified Condition
Radiator reservoir cap
Standard value (for brand new cap)
93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to psi)
Minimum standard value (after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)