VACUUM SENSOR > INSTALLATION |
for Preparation Click here
1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR |
Install the manifold absolute pressure sensor with the bolt.
- Torque:
- 7.1 N*m{ 72 kgf*cm , 63 in.*lbf }
Connect the connector.
2. INSTALL AIR CLEANER CASE SUB-ASSEMBLY |
Install the air cleaner case sub-assembly with the 2 bolts and grommet.
- Torque:
- 7.0 N*m{ 71 kgf*cm , 62 in.*lbf }
Install the air cleaner filter element sub-assembly.
3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
Install the air cleaner hose sub-assembly and lock the hose clamp.
Text in Illustration *a Engine Side *b 75° - NOTICE:
- Align the groove of the air cleaner hose with the tab of the throttle with motor body assembly and install the hose.
- Make sure that the tab of the air cleaner hose clamp stays within the range shown by *b.
Install the air cleaner cap sub-assembly with the 2 clamps.
Connect the wire harness clamp.
Connect the mass air flow meter connector.
Connect the purge VSV.
Connect the ventilation hose.