VACUUM SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR
  1. Install the manifold absolute pressure sensor with the bolt.

    Torque:
    7.1 N*m{ 72 kgf*cm , 63 in.*lbf }
  1. Connect the connector.



2. INSTALL AIR CLEANER CASE SUB-ASSEMBLY
  1. Install the air cleaner case sub-assembly with the 2 bolts and grommet.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }
  1. Install the air cleaner filter element sub-assembly.



3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    A267399E01
  1. Install the air cleaner hose sub-assembly and lock the hose clamp.

    Text in Illustration 
    *a
    Engine Side
    *b
    75°

    NOTICE:
    1. Align the groove of the air cleaner hose with the tab of the throttle with motor body assembly and install the hose.
    2. Make sure that the tab of the air cleaner hose clamp stays within the range shown by *b.
  1. Install the air cleaner cap sub-assembly with the 2 clamps.

  1. Connect the wire harness clamp.

  1. Connect the mass air flow meter connector.

  1. Connect the purge VSV.

  1. Connect the ventilation hose.