2KD-FTV EMISSION CONTROL > SERVICE DATA



EGR VALVE (for DPF) 
Tester Connection
Condition
Specified Condition
5 (M-) - 4 (M+)
25°C (77°F)
0.3 to 100 Ω

EGR VALVE (w/ EGR Cooler) 
Tester Connection
Condition
Specified Condition
1 (VC) - 2 (E2)
20°C (68°F)
2.8 to 7.8 kΩ
3 (EGLS) - 2 (E2)
20°C (68°F)
Fully opened
2.0 to 7.0 kΩ
20°C (68°F)
Fully closed
0.1 to 2.5 kΩ

EGR VALVE (w/o EGR Cooler) 
Tester Connection
Condition
Specified Condition
1 (VC) - 2 (E2)
20°C (68°F)
2.8 to 7.8 kΩ
3 (EGLS) - 2 (E2)
20°C (68°F)
Fully opened
w/ Intercooler
2.0 to 7.0 kΩ
w/o Intercooler
2.0 to 7.0 kΩ
20°C (68°F)
Fully closed
w/ Intercooler
0.1 to 2.5 kΩ
w/o Intercooler
0.1 to 2.5 kΩ

EXHAUST GAS TEMPERATURE SENSOR 
Item
Tester Connection
Condition
Specified Condition
Exhaust gas temperature sensor
1 - 2
50°C (122°F)
82 to 137 kΩ
No. 2 exhaust gas temperature sensor
1 - 2
50°C (122°F)
82 to 137 kΩ
No. 3 exhaust gas temperature sensor
1 - 2
50°C (122°F)
82 to 137 kΩ

EXHAUST FUEL ADDITION INJECTOR 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
7.1 to 7.9 Ω

VACUUM REGULATING VALVE (w/ EGR System with EGR Cooler) 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
11 to 13 Ω

VACUUM REGULATING VALVE (w/ EGR System without EGR Cooler) 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
11 to 13 Ω

VACUUM SWITCHING VALVE 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
37 to 44 Ω

VACUUM SWITCHING VALVE (for DPF) 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
37 to 44 Ω

VACUUM SWITCHING VALVE (w/ EGR Cooler) 
Item
Tester Connection
Condition
Specified Condition
No. 1 vacuum switching valve (for EGR Cut)
1 - 2
20°C (68°F)
37 to 44 Ω
No. 2 vacuum switching valve (for No. 2 EGR)
1 - 2
20°C (68°F)
37 to 44 Ω

AIR FUEL RATIO SENSOR 
Tester Connection
Condition
Specified Condition
1 (HAF2) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω