CHARGING SYSTEM > Charge Warning Light Comes ON while Driving |
for Preparation Click here
INSPECTION PROCEDURE
1.CHECK LOCK FUNCTION OF CLUTCH PULLEY |
Check the lock function with the pulley installed in the vehicle.
Visually check that the rotor in the generator operates with the engine started.
Check the lock function with the pulley removed from the vehicle.
Remove the generator pulley cap. Using SST, hold the generator rotor.
Turn the clutch pulley clockwise and check that the outer ring locks.
- OK:
- The outer ring locks.
- SST
- 09820-63020
|
| ||||
OK | |
2.CHECK LOCK OF CLUTCH PULLEY |
Start the engine and visually check looseness of the clutch pulley.
- OK:
- The clutch pulley is not loose.
|
| ||||
OK | ||
|